I hope this guide will help with your wood burning stove installation and that you may enjoy the warmth and memories it will create.
Stove pipe installation guide.
Then attach the pipe to the stove and chimney pipe making sure it is rigid and tight.
A wood stove is such a treat as not only does it provide heat but you can cook on it too and create many cherished family memories around it during the deepest darkest winter times.
Every stove is different check in your owner s manual or on the tag on the back of your wood stove.
Then connect it to the wall thimble.
Maximum overall length of straight pipe.
Through kits available always follow the specific manufacturers installation instructions.
After trimming your pipe use black furnace cement to seal between each piece and three sheet metal screws at each joint.
Also called stove pipe smoke pipe chimney connector etc the rules provided here are based on the csa installation code used in canada.
The crimped end stub of the stove pipe adapter is intended to fit inside of the flue pipe from a solid fuel appliance thus preventing condensate drips at the chimney connection.
For the exact rules in your area check with a local wood heat retailer chimney sweep or building inspector.
Minimum chimney height at sea level of a straight or vertical chimney is 10 feet to 15 feet above the appliance outlet.
Heavier gauge pipe will likely have adjustable slip joints which will eliminate the need for trimming.
Last fasten each section of stovepipe with self tapping screws.
The stove pipe must also meet minimum distances to combustible materials.
Cvs installation instructions cvs installation instructions pdf 1 17mb cvs française instructions d installation pdf 1 17mb directvent pro installation instructions directvent pro instructions pdf 2 3mb directvent pro française instructions d installation pdf 1 8mb directvent pro horizontal termination supplement pdf 1mb directvent pro vertical wind.
Remember unprotected single or double wall stove pipe should not pass through a combustible wall or ceiling to connect to the chimney.
Install the slip connector or telescoping section last.
Installation of the stove pipe is the same as for vertical installation.
Download our chimney pipe installation guide now.
3 m 10 ft.
Install inter connecting flue pipe following the appliance manufacturer s installation instructions and appropriate building.
You must use an approved method.
Start with the rigid sections and work from the stove to the wall.
Higher elevations or the use of an elbow or a tee will require approximately 30 to 60 more height to provide for an adequate draft.
In the us however nfpa 211 requires at least 36 inches of clearance from combustible materials to the side or rear of a wood stove unless something less is specified in the owner s manual or there is an engineered shield on the walls.